Summary
A command injection flaw has been identified in the formSetSafeWanWebMan function of the Tenda RX3 router, version 16.03.13.11_multi, and can be exploited remotely. The assigned CVSS 4.0 score is 10.0 (critical severity).
What happened
The flaw lies in the formSetSafeWanWebMan function of the file /goform/SetRemoteWebCfg. Manipulating the remoteIp argument results in command injection (CWE-77, CWE-74). According to the description, the attack can be carried out remotely and an exploit has been publicly released.
Why it matters
The CVSS 4.0 score is 10.0 (vector CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P), assigned by VulDB as CNA, with critical severity. The source states the exploit has been made public and may be used in attacks. The flaw is not listed in CISA's KEV catalog and active exploitation is not confirmed.
Affected products and versions
Tenda RX3, version 16.03.13.11_multi.
| Product | Versions | Fixed in |
|---|---|---|
| Tenda RX3 | 16.03.13.11_multi | — |
Action recommended by the source
The source does not state a fixed version or a vendor mitigation. Readers may consult the manufacturer's product page (https://www.tenda.com.cn/) and the VulDB references for updates.
Sources and references
- https://vuldb.com/vuln/443407 — CVE Program
- https://vuldb.com/vuln/443407/cti — CVE Program
- https://vuldb.com/cve/CVE-2026-136549 — CVE Program
- https://vuldb.com/submit/1057767 — CVE Program
- https://github.com/Zeyfrost/tenda-rx3-vulns/blob/master/cmd_injection_remoteIp/detail.md — CVE Program
- https://www.tenda.com.cn/ — CVE Program
Weaknesses (CWE): CWE-77, CWE-74
Relevant change history
Advisory correction
The preliminary version was replaced by the full write-up.
Published
Preliminary advisory published.