Summary
An exposed interface lacking authentication and authorization in several ifm O3D, O3DP and O3X devices lets an unauthenticated remote attacker send arbitrary commands. The CVSS 4.0 score is 9.3 and the severity is critical.
What happened
This is a missing authentication and authorization issue (CWE-306) on an exposed interface of the affected component. An unauthenticated remote attacker can send arbitrary commands to it, which can force the device to reboot or allow the upload of malicious firmware. The CVSS 4.0 vector is CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N (assigned by CNA:CERTVDE), with a score of 9.3. The identifier is CVE-2026-121613.
Why it matters
The attack can be carried out over the network, without privileges or user interaction, and the vector indicates high impact on the device's confidentiality, integrity and availability. Uploading malicious firmware could compromise how the device operates. CISA's KEV catalog does not list this vulnerability as exploited; the source does not state active exploitation.
Affected products and versions
ifm products and versions as listed: O3D301, O3D303, O3D305, O3D311, O3D353 and O3D355 (1.71.10735 and 1.90.107); O3D302, O3D312, O3D300, O3D310, O3D314 and O3D354 (1.71.10735 and 1.90.119); O3D304 (1.90.119); O3D361 (1.20.6381); O3DP01, O3DP03, O3DP21 and O3DP23 (2.10.16); O3X120 and O3X130 (2.0.10412). The source does not state fixed versions or upper bounds of the affected range.
| Product | Versions | Fixed in |
|---|---|---|
| ifm O3D301 | 1.71.10735 | — |
| ifm O3D301 | 1.90.107 | — |
| ifm O3D303 | 1.71.10735 | — |
| ifm O3D303 | 1.90.107 | — |
| ifm O3D305 | 1.71.10735 | — |
| ifm O3D305 | 1.90.107 | — |
| ifm O3D311 | 1.71.10735 | — |
| ifm O3D311 | 1.90.107 | — |
| ifm O3D353 | 1.71.10735 | — |
| ifm O3D353 | 1.90.107 | — |
| ifm O3D355 | 1.71.10735 | — |
| ifm O3D355 | 1.90.107 | — |
| ifm O3DP01 | 2.10.16 | — |
| ifm O3DP03 | 2.10.16 | — |
| ifm O3DP21 | 2.10.16 | — |
| ifm O3DP23 | 2.10.16 | — |
| ifm O3X120 | 2.0.10412 | — |
| ifm O3X130 | 2.0.10412 | — |
| ifm O3D361 | 1.20.6381 | — |
| ifm O3D302 | 1.71.10735 | — |
| ifm O3D312 | 1.71.10735 | — |
| ifm O3D300 | 1.71.10735 | — |
| ifm O3D310 | 1.71.10735 | — |
| ifm O3D314 | 1.71.10735 | — |
| ifm O3D354 | 1.71.10735 | — |
| ifm O3D302 | 1.90.119 | — |
| ifm O3D304 | 1.90.119 | — |
| ifm O3D312 | 1.90.119 | — |
| ifm O3D300 | 1.90.119 | — |
| ifm O3D310 | 1.90.119 | — |
| ifm O3D314 | 1.90.119 | — |
| ifm O3D354 | 1.90.119 | — |
Action recommended by the source
The source does not state a fixed version or mitigation measures. Readers are advised to consult the vendor/CERT@VDE advisory (VDE-2026-148): https://www.certvde.com/en/advisories/VDE-2026-148/
Sources and references
- https://www.certvde.com/en/advisories/VDE-2026-148/ — CVE Program
Weaknesses (CWE): CWE-306
Relevant change history
Published
Advisory published.